Solutions

Built around how the load is actually used.

From self-consumption and small commercial peak shaving to off-grid and backup power — each deployment profile is built around a clear architecture with published datasheets behind every number.

Modern suburban home with rooftop solar and wall-mounted VERZESS battery

Residential

Self-consumption with backup.

Pair a VE-HB hybrid inverter with VE-LB low-voltage battery modules (5 / 10 / 16 kWh) to shift solar into the evening and keep critical loads running through outages. Switchover under 10 ms, monitored from a phone app, paired with a single-phase or split-phase output.

    Typical array
    4 - 12 kWp
    Storage
    5 - 30 kWh
    Backup loads
    Critical circuit (sub-10 ms)
    Inverter
    VE-HB single / split-phase
Small commercial building with flat-rooftop solar and VERZESS battery cabinet

Small commercial

Cut the peak, keep the lights on.

Shops, cafés, workshops and small offices shave demand charges and survive blackouts with the same architecture scaled up: a three-phase inverter stack plus stacked battery capacity. Per-phase unbalanced output means single-phase loads still get covered during a fault.

    Typical array
    10 - 50 kWp
    Storage
    30 - 100 kWh
    Payback focus
    Demand shaving
    Inverter
    VE-HB three-phase 6 - 30 kW
Suburban home lit at night during a grid outage with VERZESS battery backup active

Backup power

When the grid goes dark, the home doesn't.

Sub-10 ms automatic switchover keeps the lights, fridge, internet and medical equipment running through an outage. The system watches grid voltage in real time and disconnects cleanly into island mode — no flicker, no manual reset.

    Switchover
    Under 10 ms
    Island mode
    Automatic, anti-islanding
    Critical load panel
    Up to whole-home backup
    Generator input
    Auto-start ready
Off-grid cabin installation with ground-mount solar and VERZESS battery bank

Weak-grid & off-grid

Systems that tolerate unstable supply.

Wide AC input windows, generator input and load-step capability make our hardware a practical choice where brownouts are weekly events — remote sites, agricultural pumps, telecom towers, islands.

90 - 280 V
AC input window
50 / 60 Hz
Dual frequency
0 - 100%
Load step capability
Yes
Generator input

Hardware & monitoring

The equipment and the eyes on it.

Wall-mounted VERZESS hybrid inverter and battery stack in utility room

Utility-room install

Clean, labelled, documented.

Wall-mounted inverter with a stacked LFP battery bank. Cable tray, labelled circuits, accessible BMS — every installation reads like an engineering drawing.

VERZESS monitoring app showing solar production and battery state of charge on a smartphone

App monitoring

Every kWh, every Watt, on your phone.

Live solar production, battery state of charge, grid import/export and load breakdown. Push notifications for outage events and firmware updates.

Send us your load profile. We will propose the layout.

Tell us the array size, expected daily kWh and the loads you want backed up. We'll come back with a bill-of-materials and a one-line diagram.